DATA CENTER COOLING & HUMIDIFICATION

Data Center Evaporative Cooling Media

Inorganic glass fiber media for data center evaporative cooling and humidification systems. Advanced Filtration Concepts helps you evaluate media requirements and plan supply for new projects and scheduled replacements.

Have dimensions or equipment information? Send them with your inquiry.

BENEFITS

Media built for cooling and humidification

Effective moisture distribution

The structured glass fiber matrix absorbs and distributes water to support evaporative cooling and humidification.

Airflow-conscious selection

Low-resistance media supports airflow through the wetted section. Select the media configuration around your system’s airflow and pressure-drop requirements.

Inorganic glass fiber construction

An alternative to cellulose-based media for projects specifying an inorganic media substrate. AFC can help review the product information required for your application.

APPLICATIONS

Match the media to your cooling system

Evaporative media provides a wetted surface where water can evaporate into a passing airstream. The cooling effect depends on entering air conditions, airflow, media configuration, and water distribution.

Direct evaporative cooling and humidification

In direct systems, air passes through wetted media, reducing its dry-bulb temperature while adding moisture. Suitability depends on the facility’s temperature and humidity requirements and the system’s controls.

Indirect evaporative cooling applications

Indirect systems use a separate airstream and a heat exchanger to provide cooling without intentionally adding moisture to the supply airstream. Where the equipment incorporates a wetted-media section, replacement media must be selected for that specific section and equipment design.

Not every data center cooling system uses evaporative media. Share your equipment details so AFC can review whether this product is appropriate for your application.

PRODUCT DETAIL

A closer look at the media

Tall evap media with clean background

AFC supplies EFS inorganic glass fiber evaporative media for cooling and humidification applications. Its impregnated glass fiber matrix is designed to promote water absorption and distribution while maintaining low airflow resistance.

Media Characteristics
Product CharacteristicInformation
Media MaterialInorganic glass fiber
ConstructionImpregnated glass fiber matrix
Operating PrincipleEvaporative cooling and humidification
Water AbsorptionDesigned for effective moisture absorption and distribution
Selection ConsiderationsDimensions, media depth, airflow, allowable pressure drop, water distribution, and equipment requirements
Technical DocumentationContact AFC for current product information and application review

Performance depends on media selection, installation, entering air conditions, water quality, water distribution, and maintenance.

REPLACEMENT SUPPORT

Plan your next media replacement with AFC

Whether you are reviewing media for a new project or preparing for a scheduled replacement, start with the details that determine fit and performance.

01

Share System Information

Send the equipment manufacturer and model, existing media dimensions, quantities, and photos. Include operating information or project specifications when available.

02

Review media Requirements

Work with AFC to review the requested media construction, configuration, and documentation. Identify compatibility questions before ordering.

03

Coordinate the next steps

Request a quote, confirm availability and lead time, and discuss delivery timing. If installation support is needed, include the site location and scope so AFC can review service availability.

FAQ

Questions about data center evaporative media

Is this the same as an air filter?

No. Evaporative media is primarily a wetted surface for cooling and humidification. It does not replace the particulate filtration specified for your air-handling system.

Can it replace the media in our existing equipment?

Compatibility must be reviewed for the equipment and operating conditions. Share the manufacturer, model, existing media information, and dimensions. Size alone does not establish a suitable replacement.

Does evaporative cooling add humidity to the data hall?

Direct evaporative cooling adds moisture to the treated airstream. Indirect evaporative cooling keeps the evaporatively treated airstream separate from the supply airstream through a heat exchanger. The effect on the data hall depends on the equipment configuration and controls.

How often should the media be inspected or replaced?

Follow the equipment manufacturer’s inspection and maintenance guidance. Media condition and replacement timing depend on operating hours, water quality, deposits, physical condition, and changes in system performance. Include observations or photos with your inquiry if you are assessing a replacement.

What should I send for a quote?

Include the media height, width, depth, quantity, equipment information, and delivery location. Photos, drawings, existing part numbers, and your target project date can help clarify the request. If some details are unknown, send what you have.

CONTACT

Let’s review your data center media requirements

Tell us about your equipment, project, or planned replacement. AFC can help you review media requirements, request current technical information, and confirm the next steps for a quote.

Request a Media Quote

Scroll to Top